OpenTender 9 Nov 2026, 10:00 (UTC+01:00)

Hochtemperaturfähiger Curvetracer - PR1232549-2790-W

At a glance

Fraunhofer-Gesellschaft - Einkauf B12 is procuring Instruments for measuring electrical quantities (CPV 38341300) in Erlangen, Kreisfreie Stadt (DE252). The notice gives 9 November 2026, 10:00 (UTC+01:00) as the deadline. Procedure type: Open.

From the notice

Hochtemperaturfähiger Curvetracer

Key facts

Each fact is from the official notice, last checked 6 November 2026, 13:30 (UTC+01:00).

Status
OpenOfficial notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
Deadline
(in 2 days)Official notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
Buyer
Fraunhofer-Gesellschaft - Einkauf B12, München, DEOfficial notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
Place of performance
Erlangen, Kreisfreie Stadt (DE252)Official notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
Main CPV
Instruments for measuring electrical quantities (CPV 38341300)Official notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
Procedure
OpenOfficial notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
Lots
1Official notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
First published
8 October 2026, 15:11 (UTC+02:00)Official notice · checked 6 Nov 2026, 13:30 (UTC+01:00)
Last published
23 October 2026, 11:46 (UTC+02:00)Official notice · checked 6 Nov 2026, 13:30 (UTC+01:00)

Fact sheet

Inteliwert fact sheet: Hochtemperaturfähiger Curvetracer - PR1232549-2790-W — Fraunhofer-Gesellschaft - Einkauf B12, deadline 9 November 2026, 10:00 (UTC+01:00). A product of Bandpey GmbH.
The key facts of this page as an image (PNG, 1600 × 900), made from the official notice. © Bandpey GmbH; terms of use. Download the fact sheet

Lots (1)

  1. Lot LOT-0000: Hochtemperaturfähiger Curvetracer - PR1232549-2790-W

    Hochtemperaturfähiger Curvetracer Optionen 1.1.5 Sperrkennlinie Messung von Leckströmen bis zu einer Spannung von 5kV Stromauflösung der Messung der Sperrkennlinie besser als 1nA 1.1.10 CV-Messungen Messung von C-V Kennlinien und Bauteilkapazitäten 1.1.11 Switch Matrix Switch Matrix zur sequentiellen Messung von mindestens 6 Bauteilen ohne manuelle Änderung der Verkabelung / Kontaktierung der Prüflinge. Für den Fall einer Beeinträchtigung der Messgenauigkeit durch die Switch Matrix: Möglichkeit zum Anschluss der Prüflinge direkt an der SMU für Messungen mit erhöhten Anforderungen an die Messgenauigkeit 1.1.12 Hochstrom Ausgangskennlinie Zusätzliche Messung von Ausgangskennlinien nach 1.1.1 bis 5kA 3.2 Entladeschaltung Automatische Entladung der Prüflinge nach Öffnung der Messkammer 3.3 Spannungswächter Überwachung der Spannung am Prüfling; Verriegelung der Prüfraumtür bis die Spannung unter Schutzkleinspannung (60V) gefallen ist. 5.1 Kalibrierung Jährliche Kalibrierung im Rahmen der durchzuführenden Wartung (Pos. 5.2) 5.2 Wartung Wartungsvertrag, Laufzeit gem. dem beiliegenden Wartungsvertrag

    CPV
    Instruments for measuring electrical quantities (CPV 38341300)
    Place
    Erlangen, Kreisfreie Stadt (DE252)
    Deadline

Timeline

  1. 8 October 2026, 15:11 (UTC+02:00): Original notice Notice, version 01 (Contract or concession notice – standard regime). Official notice
  2. 23 October 2026, 11:46 (UTC+02:00): Change Notice, version 01 (Contract or concession notice – standard regime). Official notice

Buyer and place

Buyer

Fraunhofer-Gesellschaft - Einkauf B12
München, DE

Place of performance

  • Erlangen, Kreisfreie Stadt (DE252)

Classification

CPV codes

  • 38341300: Instruments for measuring electrical quantities

NUTS regions

  • DE252: Erlangen, Kreisfreie Stadt

Official documents

Links go to the publisher. Inteliwert does not copy the documents.

Questions and answers

When is the deadline?

The official notice gives 9 November 2026, 10:00 (UTC+01:00) as the deadline.

Who is the buyer?

Fraunhofer-Gesellschaft - Einkauf B12, München, DE.

What is being procured (CPV)?

Instruments for measuring electrical quantities (CPV 38341300).

Where is the work performed (NUTS)?

Erlangen, Kreisfreie Stadt (DE252).

Is it divided into lots?

No, the notice names a single lot.

Which procedure is used?

Open.

How do I submit a bid?

On the official notice or the portal it names. Inteliwert does not submit bids. Official notice

Am I eligible?

Inteliwert does not judge eligibility. The selection criteria are in the official notice. Official notice

Companies that might fit

Possible match based on public information

Companies Inteliwert knows from its sources, not the whole market. Inteliwert does not judge eligibility, fit or chances.

  • SME (from the award notice)
    • Won a contract in CPV group 380 (2026-03-16) Evidence · checked 4 Nov 2026
    • Seat in the same country as the place of performance Evidence · checked 4 Nov 2026
  • SME (from the award notice)
    • Won a contract in CPV group 384 (2026-10-29) Evidence · checked 4 Nov 2026
    • Seat in the same country as the place of performance Evidence · checked 4 Nov 2026
  • SME (from the award notice)New to public tenders
    • Won a contract in CPV group 380 (2026-10-27) Evidence · checked 4 Nov 2026
    • Seat in the same country as the place of performance Evidence · checked 4 Nov 2026
  • SME (from the award notice)New to public tenders
    • Won a contract in CPV group 380 (2026-10-07) Evidence · checked 4 Nov 2026
    • Seat in the same country as the place of performance Evidence · checked 4 Nov 2026
  • SME (from the award notice)New to public tenders
    • Won a contract in CPV group 380 (2026-10-23) Evidence · checked 4 Nov 2026
    • Seat in the same country as the place of performance Evidence · checked 4 Nov 2026

More from this buyer

Other published opportunities of this buyer in the indexed notices, open ones first.

Source

Publisher
Bekanntmachungsservice
Licence
CC0 1.0
Last checked
6 November 2026, 13:30 (UTC+01:00)

The official notice is authoritative. Inteliwert shows what the notice states and links to it.

Markdown version